Belling GHU75C 75cm 5 Burner Gas Hob Stainless MPN 444410133
N508
- Dispatched in 2-3 days
- 30 Day Return Policy
- In stock, ready to ship
- Backordered, shipping soon
Belling GHU75C 75cm Gas Hob
Five Burners | Stainless Steel | Product Code 444410133
The Belling GHU75C is a 750mm stainless-steel built-in gas hob with five burners, including a 3.6kW wok burner. It provides automatic ignition, front rotary controls, removable cast-enamel pan supports and flame-failure protection. Correct installation depends on the exact product code, worktop cut-out, clearances, ventilation, gas configuration and completion of the official safety modification.
Key Features
- ✔ Five gas burners including central wok burner
- ✔ Automatic spark ignition
- ✔ Flame-failure safety device
- ✔ Stainless pressed-hob surface
- ✔ Removable cast-enamel pan supports
- ✔ Front-mounted rotary controls
Technical Specs
| Product code | 444410133 |
| Overall size | 750 W x 510 D x 101 H mm |
| Worktop cut-out | 560 W x 480 D mm |
| Minimum clearance above | 700mm |
| Burner outputs | 3.6 / 3.0 / 1.75 / 1.75 / 1.0kW |
| Ignition supply | 220-240V, 13A connection |
| Finish | Stainless steel / silver |
Compatibility / Fitment Guide
| Installation Check | Required | Not Compatible / Do Not Assume |
|---|---|---|
| Identity | Rating plate identifies Belling GHU75C, product code 444410133. | Do not confuse with factory-LPG GHU75C code 444410446 or other GHU75/GTG75 variants. |
| Worktop aperture | Finished cut-out is 560 x 480mm and supports/clamps match the Belling installation instructions. | Not a direct fit where an existing aperture is larger, structurally weak or lacks the specified edge clearances. |
| Space envelope | At least 750 x 510mm top area, 101mm appliance depth below the surface, and room for gas/electrical connections without strain. | Check drawers, bulkheads, insulation and pipe routes below; nominal 75cm width alone is insufficient. |
| Overhead clearance | Minimum 700mm clear space above the hob, plus any greater clearance specified by a hood or surrounding material. | Do not install below combustible shelves or fittings that breach the installation manual. |
| Gas type | Gas supply, pressure, injectors and regulator match the rating plate and current installation instructions. | Code 444410133 must not be advertised or connected as factory LPG merely because an LPG conversion may be possible. Any conversion is for a qualified installer using the correct approved components. |
| Electrical | Safe 220-240V supply and accessible 13A connection for ignition, installed in a dry permitted location. | Not a non-electric hob; automatic ignition requires mains power. |
| Boat / caravan use | A Gas Safe engineer competent in LPG/leisure installations confirms ventilation, flame stability, gas locker, isolation and applicable regulations. | Domestic product dimensions do not by themselves establish suitability for a boat, caravan or motorhome. |
| OPSS modification | Belling confirms the individual hob has received the gas-elbow corrective modification. | An unverified or unmodified unit must not be connected for use; owners using LPG were instructed to disconnect affected appliances immediately. |
Part Number Cross Reference
| Belling product code / MPN | 444410133 |
| Belling model designation | GHU75C stainless (also marketed as GHU75GC) |
| EAN | 5052263101333 |
| 4Boats SKU | N508 |
| Different factory-LPG model | 444410446 — not the same product code |
Frequently Asked Questions
Is product code 444410133 an LPG hob?
It is not the separate factory-LPG code 444410446. Read the rating plate and have a qualified engineer confirm the gas configuration. Never infer gas type from appearance or model-family name.
Will it replace any 75cm hob?
No. Measure the 560 x 480mm cut-out, overall 750 x 510mm footprint, 101mm depth, overhead clearance and all service connections.
Can it be installed on a boat or caravan?
Only after a qualified installer confirms that the appliance, ventilation, gas system, flame stability, electrical supply and applicable leisure/marine regulations are suitable.
What does the safety notice mean?
OPSS identified affected gas-supply elbow joints that can leak even when the hob is not in use. Belling must confirm that the official modification has been completed for the individual appliance.
Who should install it?
A suitably qualified Gas Safe registered engineer; LPG and leisure installations require the appropriate competence.
Safety contact: The official OPSS corrective-action notice directs affected owners to Belling. Freephone listed by OPSS: 0800 041 8831. If gas is smelled, isolate only if safe to do so, leave the area and use the appropriate national gas emergency service.
For the products under £150 the shipping is £6.99.